Dosing systems for pH and chlorine

dosing pump

 

 

dosing pump  

 

dosing pump

Automatic processing of the water without manual intervention of the products is today possible thanks to the system of automatic control that analyses and rule the acidity of the water and its agents disinfectants.
Particularly suitable for swimming pools with an important volume of water, the system of automatic control brings comfort to bathers, good water quality and saving on products of treatment.
Studied of the need to offer to customers a practical and accurate system that in accordance with the existing regulations of swimming pools, allow the monitoring, control and determination of the two main parameters of pool water redox and pH, the integrated system Regula 2 is extremely simple and easy installation.
Offers all the advantages associated use of instrumentation extremely reliable and precise, subject to strict tests and built in accordance with the rules more restrictive in terms of electronic parts and security in working environment.
The integrated system Regula 2 is composed of: panel in PVC prepared for wall mounting and with the following equipment assembled :
— Electronic control unit mod. REGULA 2 in waterproof box, IP 65 protection, dim. 295 x H x 255 P 120 mm.
Terminal blocks compartment section separated from electronics, easily accessible and with serigraphs to the side of the terminals to the speed and simplify the operation of electrical connections. Liquid Crystal Display for the reading of the values of Rx/MV and pH. Power supply 125/220/240 V AC.
Main technical features:
Section pH: Measuring field: 2-12 pH
Entrance from electrode of pH with a direct connection in terminal block.
Exit ON/OFF: 1 exchange set with voltage 125/220/240 V AC. Maximum load 3a resistive on 250 V AC.
Protection fuse. Exit for repetition signal.
Section redox: Measuring field: 0 + 1000 mV
Entrance from electrode of redox with a direct connection in terminal block.
Exit ON/OFF: 1 exchange set with voltage 125/220/240 V AC. Maximum load 3a resistive on 250 V AC.
Protection fuse. Exit for repetition signal.
— Probe SFP outflow to cup with transparent polycarbonate liable to contain electrode MT 401 gel (pH),
Electrode PT 4,800 platinum (mV chlorine). Complete of coaxial cables to standards EN. Length 5 M cables
— N° 2 Electronic dosing pumps equipment for the dosing of acid and chlorine.
Power supply connection direct from the controller Regula 2. 125/220/240 V AC. Command ON/OFF direct electronic control unit.
Flow manually adjustable through appropriate knob. Possibility of reduction of full scale to 1/5 of the maximum capacity. ready for the contact of level. Protection of the panel commands with inserts in transparent polycarbonate and on gasket. Checkout and back cover aluminium protected with epoxy paint. Max. capacity 10 litres/hour to 500 kPA (5 Bar) max.
— The system is equipped by:
n° 2 buffer solutions for the calibration of the pH section
n° 1 Buffer solution for the calibration of the RX section
n° 1 User manual for the installation and maintenance of the system REGULA 2
n° 1 Schematic diagram for the construction of the curve MV/ppm chlorine. This diagram is positioned directly on the panel, easily visible to an immediate comparison of the value MV indicated from the controller with the value expressed in ppm from normal DPD portable systems.

Request a customized offert for your swimming pool

 